Military Embedded Systems

Advanced MIL-STD-1553 Test & Simulation PC/104-Plus modules

Eletter Product

Advanced MIL-STD-1553 Test & Simulation PC/104-Plus modules are targeted to embedded MIL-STD-1553A/B applications. The AP104-1553-x Full function version concurrently acts as the Bus controller, Multiple Remote Terminals (31) & Chronological/Mailbox Bus Monitor. Single Function or Simulator only versions are available as well as extended temperature range variants. All AP104-1553-x cards include support for IRIG-B Time Encoding/Decoding and are capable of handling 8 General Purpose Discrete I/O (GPIO) signals or Trigger I/O. A Full function Application Programming Interface (API) is also provided.

Advanced MIL-STD-1553 Test & Simulation PC/104-Plus modules are targeted to embedded MIL-STD-1553A/B applications. The AP104-1553-x Full function version concurrently acts as the Bus controller, Multiple Remote Terminals (31) & Chronological/Mailbox Bus Monitor. Single Function or Simulator only versions are available as well as extended temperature range variants. All AP104-1553-x cards include support for IRIG-B Time Encoding/Decoding and are capable of handling 8 General Purpose Discrete I/O (GPIO) signals or Trigger I/O. A Full function Application Programming Interface (API) is also provided.

Key features of the Bus Controller Mode:

  • Autonomous operation including sequencing of Minor/Major Frames
  • Acyclic message insertion/deletion
  • Programmable BC Retry without host interaction
  • Full Error Injection down to word and bit level
  • Multi-Buffering with Real Time Data Buffer Updates
  • Synchronization of BC operation to external Trigger Inputs
  • 4µs Inter Message Gap
  • Start on external Trigger Input or Digital Input

Key features of the Remote Terminal Mode:

  • Programmable Response Time for each RT with fast RT Response at 4µs
  • Programmable & Intelligent Response to Mode Codes
  • Full Error Injection down to word and bit level
  • Multi-Buffering with Real Time Data Buffer Updates

Key features of the Chronological Bus Monitor:

  • 100% Data capture on all streams at full bus rates
  • Autonomous message synchronization and Full Error Detection
  • Two Dynamic Complex Trigger with sequencing
  • Message Filter and Selective Capture
  • Bus Activity recording independent from trigger and capture mode
  • External Trigger Outputs
  • Programmable Response Timeout

 